Detailed Description
2.4 Program test
Mode Group, Channel, Program Operation, Reset Response (K1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-23
The following options are available for changing the dry run feedrate:
1. Dry run feedrate is the maximum of the programmed feedrate and setting data SD42101.
2. Dry run feedrate is the minimum of the programmed feedrate and setting data SD42101.
3. Dry run feedrate is setting SD42101, regardless of the programmed feedrate.
A dry run feedrate can be selected in the automatic modes and activated on interruption of
an automatic mode or end of a block.
For more information on feedrate control, refer to:
References:
/FB1/ Description of Functions, Basic Machine; Feeds (V1)
Display
Active dry run feedrate mode is indicated by a reversal in the relevant field in the status line
on the operator interface.
2.4.4 Skip part-program blocks
Identification
The operating function must be selected, the function must be activated, and the blocks in
question must be identified with a slash character.
Functionality
When testing or breaking in new programs, it is useful to be able to disable or skip certain
part program blocks during program execution.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals