Detailed Description
2.3 Feedrate control
Feeds (V1)
2-32 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Evaluation
The effect of:
SD42100 DRY_RUN_FEED
can be controlled using an additional setting data:
SD42101 DRY_RUN_FEED_MODE.
Effectivity SD42101
DRY_RUN_FEED_MODE
As long as the "Activate dry run feedrate" interface signal is set, instead
of the programmed feedrates, the feedrate value set in
SD42100 DRY_RUN_FEED
is effective as follows:
0 The maximum value from SD42100 DRY_RUN_FEED and the
programmed velocity is effective. This is the same as the default setting.
1 The minimum value from SD42100 DRY_RUN_FEED and the
programmed velocity is effective.
2 Setting data SD42100 DRY_RUN_FEED is effective directly, regardless
of the programmed velocity.
3 -9 Reserved
10 As for configured value 0 except for thread cutting (G33,G34,G35) and
tapping (G33,G34,G35). These functions are executed as
programmed.
11 As for configured value 1 except for thread cutting (G33,G34,G35) and
tapping (G33,G34,G35). These functions are executed as
programmed.
12 As for configured value 2 except for thread cutting (G33,G34,G35) and
tapping (G33,G34,G35). These functions are executed as
programmed.
A dry run feedrate can be selected in the automatic modes and activated on interruption of
an automatic mode or end of a block.
If the machine data setting:
MD10704 DRYRUN_MASK = 1
is set, the dry run feedrate can also be activated during execution of the program (in the part
program block).
Note
Activation during machining triggers an internal reorganization task on the control which
causes the axes to be stopped for a short time. This can affect the surface finish of the
workpiece being machined.