EasyManuals Logo

Siemens SINUMERIK ONE MCP 2400.4c Function Manual

Siemens SINUMERIK ONE MCP 2400.4c
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #296 background imageLoading...
Page #296 background image
Detailed Description
2.4 Drive service display (for digital drives only)
Diagnostic Tools (D1)
2-22 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Power section in i²t limitation HMI SW 6.3 and later
Limitation for protecting the power section against continuous overloading of the
SIMODRIVE 611 drives.
State 1: i
2
t power section limitation has responded
State 0: i
2
t power section limitation has not responded
The display applies to SIMODRIVE universal and SIMODRIVE digital.
The display corresponds to IS "i
2
t monitoring"
(DB31, ... DBX95.7).
References: /FB1/, A2, "Various Interface Signals"
Heatsink temperature warning
Warning signal output by drive:
State 0: The heatsink temperature monitoring has not responded.
State 1: The heatsink temperature monitoring has responded.
Display corresponds to IS "Heatsink-temperature prewarning"
(DB31, ... DBX94.1).
References: /FB1/, A2, "Various Interface Signals"
Motor temperature warning
Warning signal output by drive:
State 0: The motor temperature is below the warning threshold.
State 1: The motor temperature has exceeded the defined warning threshold.
The warning threshold corresponds to machine datum:
MD1602 $MD_MOTOR_TEMP_WARN_LIMIT (maximum motor temperature).
Display corresponds to IS "Motor-temperature prewarning"
(DB31, ... DBX94.0).
References: /FB1/, A2, "Various Interface Signals"
Ramp-up function completed
Status display of drive.
State 0: The ramp-up function has not yet been completed after a new speed setpoint was
defined.
State 1: The actual speed value has reached the speed tolerance band after a new speed
setpoint was defined.
The speed tolerance band corresponds to machine datum:
MD1426 $MD_SPEED_DES_EQ_ACT_TOL (tolerance band for 'n
desired
-n
actual
' message).
Display corresponds to IS "Ramp-up function completed"
(DB31, ... DBX92.2).
References: /FB1/, A2, "Various Interface Signals"

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals