Page #34 background imageLoading...
Page #34 background image
Detailed Description
2.1 NC/PLC interface signals
Various NC/PLC Interface Signals and Functions (A2)
2-22 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
DB31, ... DBX94.3 (|Md| < Mdx)
This signal indicates that the current torque |M
d
| is less than the assigned threshold torque
M
dx
:
MD1428 $MD_TORQUE_THRESHOLD_X
The threshold torque is entered as a percentage of the current speeddependent torque
limitation.
DB31, ... DBX94.4 (|nact| < nmin)
This signal indicates that the actual speed value |n
actual
| is less than the set minimum speed
n
min
:
MD1418 $MD_SPEED_THRESHOLD_MIN
DB31, ... DBX94.5 (|nact| < nix)
This signal indicates that the actual speed value |n
actual
| is less than the set threshold speed
x
:
MD1417 $MD_SPEED_THRESHOLD_X
DB31, ... DBX94.6 (nact = nsetp)
It is signaled to the PLC that the actual speed value n
actual
has reached the new setpoint,
taking into account the tolerance band set in the drive machine datum:
MD1426 $MD_SPEED_DES_EQ_ACT_TOL,
and is still within the tolerance band.
DB31, ... DBX94.7 (variable signaling function) (not 810D)
Using the variable signaling function, it is possible to monitor digitally for any axis any
variable from SIMODRIVE 611 to check if it violates a certain threshold and to signal as an
interface signal to the PLC.
The variable to be monitored is specified with 611D machine data.
DB31, ... DBX95.0 (DC link voltage < warning level)
A message is sent from the drive to the PLC that the DC link voltage U
DClink
is smaller than
the DC link undervoltage threshold:
MD1604 $MD_LINK_VOLTAGE_WARN_LIMIT
DB31, ... DBX95.7 (i
2
t monitoring) (not 810D)
The variable signaling function can be used to protect the power section of the SIMODRIVE
611 universal and SIMODRIVE 611 digital drives against continuous overload. The PLC is
signaled for each axis indicating whether the i
2
t monitoring has been initiated.
The variable to be monitored is specified with 611D machine data.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals