Detailed Description
2.3 Setpoint/actual-value system
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-29
MD30242 $MA_ENC_IS_INDEPENDENT[n] (encoder is independent):
To prevent actual-value corrections influencing the actual value of an encoder defined in the same
axis, the latter must be declared independent.
0: Encoder is independent
1: Encoder is dependent
MD index for actual-value routing
The coding of the machine data index [n] for actual-value routing is:
[Encoder no.]
0 For first encoder
1 For second encoder
Examples of setpoint/actual-value routing
SINUMERIK 840D/810D with SIMODRIVE 611 digital
For machine axis "X1", the setpoint should be output digitally and actual values acquired on
drive module 4 (4th slot = index [3]).
The "logical drive number" of this module is 7.
Encoder number: 1, 2
Therefore, actual values are acquired via a direct and indirect measuring system.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals