Detailed Description
2.7 Program operation mode
Mode Group, Channel, Program Operation, Reset Response (K1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-97
The read-in disable and single-block processing behavior can be controlled using
machine data MD20106 $MC_PROG_EVENT_IGN_SINGLEBLOCK and
MD20107 $MC_PROG_EVENT_IGN_INHIBIT as follows.
MD20106 $MC_PROG_EVENT_IGN_SINGLEBLOCK
_N_PROG_EVENT_SPF makes a block change in spite of single-block mode without an
additional Start if
Bit 0 = 1 is set after the part program start event
Bit 1 = 1 is set after the part program end event
Bit 2 = 1 is set after the operator panel reset event
Bit 3 = 1 is set after the power-up event
Bit 4 = 1 is set after the first start after search event
MD 20107: PROG_EVENT_IGN_INHIBIT
_N_PROG_EVENT_SPF makes a block change in spite of read-in disable if
Bit 0 = 1 is set after the part program start event
Bit 1 = 1 is set after the part program end event
Bit 2 = 1 is set after the operator panel reset event
Bit 3 = 1 is set after the power-up event
Bit 4 = 1 is set after the first start after search event
The following restriction applies to Bit0 == 1(prog-event after part program start):
If the prog-event is ended with part program command "RET", RET always leads to an
executable block (analogous to M17).
There is no new behavior for Bit0 == 0, i.e., RET is interpreted in the interpreter and does
not lead to an "executable block".
No sequences for start/end of part program are passed:
If a user ASUB is started from the reset status, the described sequences for the event for
start/end of part program are not passed.
Settable Prog-Event properties
Machine data MD20109 $MC_PROG_EVENT_MASK_PROPERTIES can be used to
define further properties of "event-driven program calls" for specific channels in SW 6.3
and higher:
Bit0 = 0: An ASUB started from the RESET channel state is followed
by an "event-driven program call" as in earlier versions
Bit0 = 1: An ASUB started from the RESET channel state is not followed
by an "event-driven program call"
When starting a part program:
/_N_CMA_DIR/_N_PROG_EVENT_SPF is executed as a subroutine.
_N_PROG_EVENT_SPF must be ended with M17 or RET.
No return using the REPOS command is permitted; this will generate Alarm 16020
"Repositioning not possible".
Errors in the case of operator panel reset or after powerup:
If an error is present when the operator panel is reset or after powerup EMERGENCY
STOP or Mode group/NCKContinue, then _N_PROG_EVENT_SPF will onl
y be processed
after EMERGENCY STOP has been acknowledged or the error has been acknowledged
in all channels.
The following always applies to powerup:
The powerup event occurs in all channels at the same time.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals