Brief Description
1.3 Frames
Axis Types, Coordinate Systems, Frames (K2)
1-8 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Properties of the NCU global basic frames:
Can be read and written from all channels.
Can only be activated in the channels.
Up to 16 NCU global basic frames are available.
Global frames can be used to apply offsets, scale factors and mirroring operations to
channel and machine axes.
All basic frames (up to 16 global and 16 channel-specific) are chained to produce the total
basic frame. The standard configuration is designed for at least one basic frame per channel.
Settable frames can be defined as either NCU global or channel-specific.
Channel coordination
With NCU global frames, the user must ensure channel coordination and activation of the
frames (e.g., using the WAITMC command), to allow the frames to be calculated at the
desired point in the program.
Cross-channel activation of frames is not supported.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals