Detailed Description
2.1 Axes
Axis Types, Coordinate Systems, Frames (K2)
2-6 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Tool Length Compensation
Any active tool length compensation remains operative and is applied to the new geometry
axes after replacement.
The system treats tool length compensations as not yet applied for the following geometry
axes:
All geometry axes, which have been newly added to the geometry axis grouping.
All geometry axes, which have changed their positioning within the geometry axis
grouping.
Geometry axes, which retain their position within the geometry axis grouping after a
replacement operation, also retain their status with respect to tool length compensation.
RESET
MD20110 RESET_MODE_MASK
Bit 12: Reset response of the modified geometry axis assignment.
Bit 12 = 0 When machine data $MC_GEOAX_CHANGE_RESET is enabled, a modified
geometry axis assignment is cleared on Reset or end of part program. The basic
setting defined in the machine data for the geometry axis assignment is activated.
Bit 12 = 1 A modified geometry axis assignment remains active after a reset/part-program end.
MD20118 GEOAX_CHANGE_RESET
FALSE: The current configuration of the geometry axes remains unchanged on reset and
program start. With this setting, the response is identical to older software versions
without geometry axis replacement.
TRUE: The configuration of the geometry axes remains unchanged or is switched to the
basic state defined in machine data AXCONF_GEOAX_ASSIGN_TAB on Reset and
part-program end (according to machine data $MC_RESET_MODE_MASK) and on
part-program start (according to machine data$MC_START_MODE_MASK).
Program start
Analogously to the Reset response, the response on Start is determined by:
MD20112 START_MODE_MASK
Bit 12: Response of the modified geometry axis assignment.
Bit 12 = 0 A modified geometry axis assignment remains active on part-program start.
Bit 12 = 1 A modified geometry axis assignment is cleared on part-program start.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals