Detailed description
2.5 Linking PLC CPUs to 810D, 840D
Power Line Basic PLC Program (P3)
2-28 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
All values must be converted to decimal values and lined up in order of alarm or message
number:
Event ID: 46
hex
= 70
dec
Supplementary
information 1
00
hex
= 00
dec
Supplementary
information 2
20
hex
= 32
dec
Alarm number (OM)
1)
= 70 00 32
1) controlled by DB2.DBX184.0
OM = operational message
This signifies the event with Event ID 16# B046 and the indicated supplementary information
"Message 700032 deleted".
Notes
The meaning of the message number is specified by the machine manufacturer.
Events with Event ID 16# xx28 or 16# xx29 are generated from the basic program.
The messages stored in the diagnostic buffer can be read out on the MMC with the
associated message texts.