Detailed Description
2.3 Monitoring of static limits
Axis Monitoring, Protection Zones (A3)
2-24 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Effectivity
Immediately after the successful referencing of the machine axis.
In all operating modes.
Constraints
The software limit switches refer to the machine coordinate system.
The software limit switches must be inside the range of the hardware limit switches.
The machine axis can be moved to the position of the active software limit switch.
PRESET
After use of the function PRESET, the software limit switch monitoring is no longer active.
The machine must first be re-referenced.
Endlessly rotating rotary axes
No software limit switch monitoring takes place for endlessly rotating rotary axes:
MD30310 $MA_ROT_IS_MODULO == 1 (Modulo conversion for rotary axis and spindle)
Effect
Automatic operating modes (AUTOMATIC, MDI)
1. Without transformation, without overlaid movement, unchanged software limit switch:
A part program block with a programmed traversing motion that would lead to
overrunning of the software limit switch is not started.
2. With transformation:
Different reactions occur depending on the transformation type.
Behavior as under 1.
or
The part program block with a programmed traversing motion that would lead to
overrunning of the software limit switch is started. The affected machine axis stops at the
active software limit switch. The other machine axes participating in the traversing motion
are braked. The programmed contour is left during this process.
3. With overlaid motion
The part program block with a programmed traversing motion that would lead to
overrunning of the software limit switch is started. Machine axes that are traveling with
overlaid motion or have traveled with overlaid motion stop at the active software limit
switch in question. The other machine axes participating in the traversing motion are
braked. The programmed contour is left during this process.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals