No. Description Function IEC 60870-5-103 Configurable in
Matrix
Type
information number
Compatibility
Data Unit
Position
CFC
Control Display
Default Display
1041 Active Power Maximum Forward
(Pmax Forw=)
Min/Max meter - - - - - CFC CD DD
1042 Active Power Minimum Reverse
(Pmin Rev =)
Min/Max meter - - - - - CFC CD DD
1043 Active Power Maximum Reverse
(Pmax Rev =)
Min/Max meter - - - - - CFC CD DD
1044 Reactive Power Minimum Forward
(Qmin Forw=)
Min/Max meter - - - - - CFC CD DD
1045 Reactive Power Maximum Forward
(Qmax Forw=)
Min/Max meter - - - - - CFC CD DD
1046 Reactive Power Minimum Reverse
(Qmin Rev =)
Min/Max meter - - - - - CFC CD DD
1047 Reactive Power Maximum Reverse
(Qmax Rev =)
Min/Max meter - - - - - CFC CD DD
1048 Power Factor Minimum Forward
(PFminForw=)
Min/Max meter - - - - - CFC CD DD
1049 Power Factor Maximum Forward
(PFmaxForw=)
Min/Max meter - - - - - CFC CD DD
1050 Power Factor Minimum Reverse
(PFmin Rev=)
Min/Max meter - - - - - CFC CD DD
1051 Power Factor Maximum Reverse
(PFmax Rev=)
Min/Max meter - - - - - CFC CD DD
1052 Active Power Demand Forward
(Pdmd Forw=)
Demand meter - - - - - CFC CD DD
1053 Active Power Demand Reverse
(Pdmd Rev =)
Demand meter - - - - - CFC CD DD
1054 Reactive Power Demand Forward
(Qdmd Forw=)
Demand meter - - - - - CFC CD DD
1055 Reactive Power Demand Reverse
(Qdmd Rev =)
Demand meter - - - - - CFC CD DD
7731 PHI I AB (local) (Φ I AB=) Measurement - - - - - CFC CD DD
7732 PHI I BC (local) (Φ I BC=) Measurement - - - - - CFC CD DD
7733 PHI I CA (local) (Φ I CA=) Measurement - - - - - CFC CD DD
7734 PHI V AB (local) (Φ V AB=) Measurement - - - - - CFC CD DD
7735 PHI V BC (local) (Φ V BC=) Measurement - - - - - CFC CD DD
7736 PHI V CA (local) (Φ V CA=) Measurement - - - - - CFC CD DD
7737 PHI VI A (local) (Φ VI A=) Measurement - - - - - CFC CD DD
7738 PHI VI B (local) (Φ VI B=) Measurement - - - - - CFC CD DD
7739 PHI VI C (local) (Φ VI C=) Measurement - - - - - CFC CD DD
7748 Diff3I0 (Differential current 3I0)
(Diff3I0=)
IDiff/IRest - - - - - CFC CD DD
7751 Prot. Interf. FO: Transmission
delay (PI FO TD)
Measure PDI 134 122 No 9 1 CFC CD DD
Functions, Settings, Information
F.5 Measured Values
396 SIPROTEC 4, 7SD80, Manual
E50417-G1100-C474-A2, Edition 02.2018