A.8 Information List
405
7SD610 Manual
C53000-G1176-C145-4
3252 > PI1 Synchronization RESET
(>SYNC PI1 RESET)
Prot. Interface SP on
off
**LEDBIBO
3254 Prot.1: Delay time change recog-
nized (PI1 jump)
Prot. Interface OUT on
off
**LEDBO
3256 Prot.1: Delay time unsymmetry to
large (PI1 unsym.)
Prot. Interface IntSP ON
OFF
* LED BO
3258 ProtInt1:Permissible error rate
exceeded (PI1 Error)
Prot. Interface OUT on
off
**LEDBO
3260 Diff: >Commissioning state ON
(>Comm. Diff ON)
Diff. Prot SP ON
OFF
**LEDBIBO
3261 Diff: >Commissioning state OFF
(>Comm. Diff OFF)
Diff. Prot SP ON
OFF
**LEDBIBO
3262 Diff: Commissioning state
ON/OFF (Comm Diff.ONoff)
Diff. Prot IntSP ON
OFF
**LEDBO
3263 Diff: Commissioning state
ON/OFF via BI (CommDiffONoff-
BI)
Diff. Prot IntSP ON
OFF
**LEDBO
3452 > Logout state ON (>Logout ON) Diff.-Topo SP ON
OFF
**LEDBIBO
3453 > Logout state OFF (>Logout
OFF)
Diff.-Topo SP ON
OFF
**LEDBIBO
3458 System operates in a open
Chaintopology (Chaintopology)
Diff.-Topo OUT ON
OFF
* * LED BO 93 142 1 Yes
3459 Logout state ON/OFF (Logout
ON/off)
Diff.-Topo IntSP ON
OFF
**LEDBO
3460 Logout state ON/OFF via BI
(Logout ON/offBI)
Diff.-Topo IntSP ON
OFF
**LEDBO
3464 Communication topology is com-
plete (Topol complete)
Diff.-Topo OUT ON
OFF
**LEDBO
3475 Relay 1 in Logout state
(Rel1Logout)
Diff.-Topo IntSP ON
OFF
**LEDFC
TN
BO 93 143 1 Yes
3476 Relay 2 in Logout state
(Rel2Logout)
Diff.-Topo IntSP ON
OFF
**LEDFC
TN
BO 93 144 1 Yes
3484 Local activation of Logout state
(Logout)
Diff.-Topo IntSP ON
OFF
**LEDFC
TN
BO 93 149 1 Yes
3487 Equal IDs in constellation (Equal
IDs)
Diff.-Topo OUT ON
OFF
**LEDBO
3491 Relay 1 in Login state (Rel1
Login)
Diff.-Topo OUT ON
OFF
* * LED BO 93 191 1 Yes
3492 Relay 2 in Login state (Rel2
Login)
Diff.-Topo OUT ON
OFF
* * LED BO 93 192 1 Yes
3501 I.Trip: >Intertrip L1 signal input
(>Intertrip L1)
Intertrip SP ON
OFF
**LEDBIBO
3502 I.Trip: >Intertrip L2 signal input
(>Intertrip L2)
Intertrip SP ON
OFF
**LEDBIBO
3503 I.Trip: >Intertrip L3 signal input
(>Intertrip L3)
Intertrip SP ON
OFF
**LEDBIBO
3504 I.Trip: >Intertrip 3 pole signal
input (>Intertrip 3pol)
Intertrip SP ON
OFF
**LEDBIBO
3505 I.Trip: Received at Prot.Interface
1 L1 (ITrp.rec.PI1.L1)
Intertrip OUT on
off
**LEDBO
3506 I.Trip: Received at Prot.Interface
1 L2 (ITrp.rec.PI1.L2)
Intertrip OUT on
off
**LEDBO
3507 I.Trip: Received at Prot.Interface
1 L3 (ITrp.rec.PI1.L3)
Intertrip OUT on
off
**LEDBO
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation