SIRIUS 3RW5 Modbus TCP communication module
Manual, 03/2018, A5E43676481002A/RS-AA/001
63
Maintenance and service
8
8.1
Firmware update
During operation, it may be necessary to update the firmware (e.g. to extend the available
functions). You update the firmware of the device with the help of firmware files. The
retentive data is retained after the firmware has been updated.
Firmware updates are provided to you on the Internet. You can perform a firmware update
for the following devices:
3RW5 soft starter
3RW5 HMI High Feature
3RW5 communication module
Requirements
Valid firmware update
Link (https://support.industry.siemens.com/cs/ww/en/ps/16212/dl)
Procedure
1. Make sure that the motor is switched off and you do not start the motor during the
firmware update.
A control command for starting the motor is not supported during the firmware update.
Make sure that the main supply voltage is only applied to the 3RW5 soft starter when it is
necessary.
2. Perform the update of the device firmware.
The following procedures are possible:
With a micro SD memory card via the 3RW5 HMI High Feature (Page 64)
Via SIRIUS Soft Starter ES (TIA Portal) via the LAN interface on the 3RW5 HMI High
Feature
Result
You have performed a firmware update for the selected device. The selected device
automatically restarts and the firmware update is documented in the device logbook.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIRIUS 3RW5 series and is the answer not in the manual?

Siemens SIRIUS 3RW5 series Specifications

General IconGeneral
BrandSiemens
ModelSIRIUS 3RW5 series
CategoryController
LanguageEnglish

Related product manuals