Communication
11.9 DR 6 Limits
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa 123
11.9.8 Delay for belt speed limits
Violation of the limits for the belt speed is delayed by the specified time. The specification is
made in ms.
11.9.9 Minimum belt load
Dropping below the minimum belt load is displayed in the status area of the belt scale. The
specification is made in % of the nominal belt load which was determined during
commissioning.
11.9.10 Maximum belt load
Exceeding the maximum belt load is displayed in the status area of the belt scale. The
specification is made in % of the nominal belt load which was determined during
commissioning.
11.9.11 Delay for belt load limits
Violation of the limits for the belt load is delayed by the specified time. The specification is
made in ms.
11.9.12 Medium load for totalizing
Totalizing is not carried out below this value. The specification is made in % of the belt load.
If "0" is specified, totalizing is bidirectional.