Communication   
11.13 DR 10 load cell parameters 
  SIWAREX WT241 
136  Manual, 05/2015, A5E36046748A 
11.13.2  50/60 Hz toggling 
To improve the suppression of faults caused by the supply network, you can specify the 
network frequency for signal filtering. 
11.13.3  Load cell characteristic value 
The characteristic value of the load cell(s) is required to correctly interpret the output voltage 
from the load cell. The exact value can be entered if the measurement log for the load cell is 
available. The mean value of all characteristic values is used if there is more than one load 
cell. 
Example 
Characteristic value = 2.018 mV/V 
11.13.4  Rated load of a load cell 
The rated load of a load cell is required for checking the maximum weighing range of the 
scales. The rated load is entered in the specified units of weight.