Communication 
  11.10 DR 7 Process interfaces 
SIWAREX WT241 
Manual, 05/2015, A5E36046748Aa  125 
11.10  DR 7 Process interfaces 
Data record DR 7 contains the parameters for defining the properties of the available I/O 
modules (digital inputs, digital outputs, analog output, serial ports). 
If a port is not used, the default value can be retained. 
Procedure 
●  Change the parameters if necessary 
●  Transfer the data record to the scale 
Table 11- 8  Assignment of data record 7 
Contains no. of data record 
Data record length information 
Information about which application the 
DR belongs to 
Information about current data record 
version 
Assignment 
digital input 
DI 0, 1, 2, 3 
(Page 128) 
Assignment of digital input .0 
Code 0: No command assigned 
1 … n: command number, is triggered at 
a rising edge (0->1 transition), 1304 
pulse sensor  
Assignment of digital input .1 
Code 0: No command assigned 
1 … n: command number, is triggered at 
a rising edge (0->1 transition)  
Assignment of digital input .2 
Code 0: No command assigned 
1 … n: command number, is triggered at 
a rising edge (0->1 transition) 
Assignment of digital input .3 
Code 0: No command assigned 
1 … n: command number, is triggered at 
a rising edge (0->1 transition) 
Input filter-
ing (hard-
ware 
setting) 
(Page 128) 
0: 0.2 ms 
1: 0.2 ms 
2: 0.4 ms 
3: 0.8 ms 
4: 1.6 ms 
5: 3.2 ms 
6: 6.4 ms 
7: 12.8 ms  
Assignment 
digital out-
put DQ 0, 
1, 2, 3 
(Page 128) 
Assignment of digital output .0 
100…131: Bit no. of the status flags 
from bytes 0 to 3 (DR 30), but inverted 
33: data record 18 
34: S7 I/O modules