Communication 
  11.19 DR 18 Control digital output 
SIWAREX WT241 
Manual, 05/2015, A5E36046748Aa  147 
11.19  DR 18 Control digital output 
If a digital output is defined in data record DR 7 for control with data record DR 18 (see 
Assignment digital output DQ 0, 1, 2, 3 (Page 128)), you can control this output with data 
record DR 18. Transfer is always for all four digital outputs. Only outputs which are 
configured for control by DR 18 (see DR 7 Process interfaces (Page 125)) are enabled or 
disabled in accordance with the content of data record DR 18. 
Procedure 
●  Check or adapt the desired parameter settings of the digital outputs in data record 7 
●  Define the value for digital output DQ,0, 1, 2, 3 
●  Transfer the data record to the scale 
Table 11- 19  Assignment of data record 18 
Contains no. of data 
record 
Data record length in-
formation 
Information about which 
application the DR be-
longs to 
Information about cur-
rent data record version 
Definition for 
digital output 
DQ.0, 1, 2, 3 
(Page 148)  
Definition for digital 
output 0=1 -> DQ0 out-
put enabled 
(only applies if output is 
assigned code 21, see 
DR 7) 
Definition for digital 
output 1=1 -> DQ1 out-
put enabled 
(only applies if output is 
assigned code 21, see 
DR 7) 
Definition for digital 
output 2=1 -> DQ2 out-
put enabled 
(only applies if output is 
assigned code 21, see 
DR 7) 
Definition for digital 
output 3=1 -> DQ3 out-
put enabled 
(only applies if output is 
assigned code 21, see 
DR 7)