Communication   
11.23 DR 30 Process state 
  SIWAREX WT241 
156  Manual, 05/2015, A5E36046748A 
11.23.2  Current belt load 
The current material weight of the loaded belt acting on one unit of the weigh length.  
11.23.3  Current belt load in % 
Current belt load in % of nominal belt load  
11.23.4  Current flow rate 
The current material flow rate (belt load x speed).  
11.23.5  Current flow rate in % 
The current material flow rate (belt load x speed) in % of the nominal flow rate. 
11.23.6  Current speed 
The current speed used to calculate the material flow rate. The output is made as length per 
second. 
11.23.7  Current speed in % 
The current speed used to calculate the material flow rate. The output is made in % of the 
maximum speed. 
11.23.8  Current master totalizer (S1) 
The total material flow is summed after the start-up and switching-off of service mode. 
Resetting the total is only possible using the "Load factory settings" command.  
11.23.9  Current main totalizer (S2) 
The material flow is saved in a powerfail-proof memory. It can be deleted using the "Log and 
delete" command.