Communication   
11.9 DR 6 Limits 
  SIWAREX WT241 
122  Manual, 05/2015, A5E36046748A 
11.9.1  Negative and positive zero offset in % 
Zeroing sets the current weight of the scale and the belt load to zero. The specification is 
made in % of the nominal belt load. The range refers to the original zero point of the last 
calibration.  
In the case of sales for legal trade operation, the maximum zero offset is 4%. 
11.9.2  Smallest totalized value 
The smallest totalized value is the smallest value which may be recorded with verification 
capability. 
11.9.3  Minimum flow rate 
Dropping below the minimum flow rate is displayed in the status area of the scale. The 
specification is made in % of the design flow rate.  
11.9.4  Maximum flow rate 
Exceeding the maximum flow rate is displayed in the status area of the scale. The 
specification is made in % of the design flow rate.  
11.9.5  Delay for flow rate limits 
Reaching the maximum flow rate is displayed in the status area of the scale only following 
expiry of the delay. The specification is made in ms. 
11.9.6  Minimum belt speed 
Dropping below the minimum belt speed is displayed in the status area of the scale. The 
specification is made in % of the nominal belt speed which was specified during 
commissioning or calculated. 
11.9.7  Maximum belt speed 
Exceeding the maximum belt speed is displayed in the status area of the scale. The 
specification is made in % of the nominal belt speed which was specified during 
commissioning or calculated.