Scale parameters and functions of the belt scale   
8.8 Menu 1.6 Recovery / reset 
  SIWAREX WT241 
72  Manual, 05/2015, A5E36046748A 
Belt speed simu-
lation value 
Enter the belt speed value to be simulated. 
 
8.8  Menu 1.6 Recovery / reset 
Setting the recovery point in this menu creates an image of all settings of the weighing proces-
sor. Reloading is possible anytime and will overwrite the current settings. 
 
Creates an image of all settings. Execution will not be acknowledged. 
Loads the latest created image. Execution will not be acknowledged. 
 
Load standard 
scale parameter 
 
Like "Load factory settings", but interface settings for Ethernet and Mod-
bus RTU are not reset to the factory setting. 
The command resets the SIWAREX to the "ex works" status. During this 
process:  
- all parameters and saved data (including protocol memory and logbook) 
as well as the restore point are loaded with the default values 
- all message buffers (diagnostics buffer, trace memory, etc.) are reset 
 
8.9  Menu 2.1 Messages 
Opens the message log of the weighing electronic.