Communication   
11.21 DR 20 Message configuration 
  SIWAREX WT241 
150  Manual, 05/2015, A5E36046748A 
11.21  DR 20 Message configuration 
You can suppress technological messages in data record DR 20. If you set the value for an 
individual message to "0", this message is no longer generated as if it did not exist. We 
recommend that you do not suppress messages. 
Suppressing a message 
Suppressing messages could mean that a fault in the belt scale is not recognized. 
Procedure 
●  Define the value for a message to be suppressed to 0 
●  Transfer the data record to the scale 
Table 11- 21  Assignment of data record 20 
Contains no. of data rec-
ord 
Data record length infor-
mation 
Information about which 
application the data rec-
ord belongs to 
Information about current 
data record version 
3002 Calibration procedure 
interrupted