Communication
11.23 DR 30 Process state
SIWAREX WT241
154 Manual, 05/2015, A5E36046748A
Variable
Note
Type
L
Rw
Default
Min.
Max.
Register
Belt is running
Set if belt is running
0
r
0
3004.4
Totalizing active
Set if totalizing is running
BIT
0
r
0
3004.3
Totalizing enabled
Set if totalizing is enabled
BIT
0
r
0
3004.2
Totalizing fault
Set if totalizing is faulty (when
changing to service mode)
BIT
0
r
0
3004.1
Pulse output active
(see Load per pulse
(Page 132))
Signal for quantity per pulse
BIT
0
r
0
3005.16
Reserve
Not used
BIT
0
r
0
3005.15
Simulation mode
weight enabled
Simulation mode for weight is
enabled
BIT
0
r
0
3005.14
Simulation mode
speed enabled
Simulation mode for weight is
enabled
BIT
0
r
0
3005.13
Stop watch is running
Set if stop watch has been
started by a command (e.g.
calibration command)
BIT
0
r
0
-
-
3005.12
Time buffering failed
Set if buffering of the time in
RTC has failed. Is deleted fol-
lowing setting of time.
BIT
0
r
0
-
-
3005.11
Trace enabled
Set if trace is running
BIT
0
r
0
-
-
3005.10
Operator error at digit.
input
Set in event of sync. error re-
sulting from command at digital
input
BIT
0
r
0
-
-
3005.9
Calibrated
Module is calibrated (calibration
of weight measurement and
speed)
BIT
0
r
0
-
-
3005.8
Service mode
Service mode active
BIT
0
r
0
-
-
3005.7
Calibration command
is running
Set if calibration procedure has
been triggered
BIT
0
r
0
-
-
3005.6
Write protection
Write-protect switch is enabled
BIT
0
r
0
-
-
3005.5
Analog output disrupt-
ed
Analog output fault
BIT
0
r
0
-
-
3005.4
Warm-up time is run-
ning
Warm-up time following power-
up is running
BIT
0
r
0
-
-
3005.3
Startup
Restore point startup or restore
has taken place, is deleted
again after 5 seconds
BIT
0
r
0
-
-
3005.2
Fault
Fault present
BIT
0
r
0
-
-
3005.1
1000
Group message "Operating
error" present
BIT
0
r
0
-
-
3006.16
Reserve
BIT
0
r
0
-
-
3006.15
1104
Undervoltage
BIT
0
r
0
-
-
3006.14
1105
Overload
BIT
0
r
0
-
-
3006.12
1106
Underload
BIT
0
r
0
-
-
3006.11
1002
RAM error
BIT
0
r
0
-
-
3006.10
1102
ADC error
BIT
0
r
0
-
-
3006.9
1005
BIT
0
r
0
-
-
3006.8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WT241 and is the answer not in the manual?

Siemens SIWAREX WT241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WT241
CategoryAccessories
LanguageEnglish

Related product manuals