TC35i AT Command Set
8.6 AT^SMOND
s
m
obil
e
TC35i_ATC_V02.07 Page 197 of 439 1/30/04
Confidential / Released
Bit Error rate, with value 99 indicating "not known or not detectable"
0...7 as RXQUAL values RXQUAL0 to RXQUAL7 in GSM 05.08 section 8.2.4
Notes
• To some extent, the cell monitoring commands AT^SMOND, AT^MONI, AT^MONP and AT^SMONC cover the
same parameters. The receiving level, for example, can be queried with all three commands. Yet the resulting
values may be slightly different, even though obtained over a time period of a few seconds. This is quite nor-
mal and nothing to worry about, as the cell information is permanently updated.
• During a connection, not all of the neighbour cell information can be decoded. The following restrictions apply:
- Information is updated only for neighbour cells that have already been visible at connection setup, and
continue to be included in the list of cells.
- New neighbour cells added to the list, for example after handover, cannot be displayed until the connection
is released.
• Parameters not available or invalid are left out. In this case, two consecutive commas are presented. For
example, if
<format> equals 1, the resulting response with parameter <cell> unavailable would read:
^SMOND:
<MCC>,<MNC>,<LAC>,,<BSIC>,<chann>,<RxLev>,<RxLev>Full,<RxLev>Sub,<RxQual>,<RxQual>Full,
<RxQual>Sub,<Timeslot>
OK
• Parameter sets not requested with input parameter
<format> will be left out altogether. For example, the
response for
<format>= 12 will read:
^SMOND:
<TA>,<RSSI>,<BER>
OK
• For compatibility with earlier products and to support legacy applications, often any input character will stop
the periodic output of the write command. But since this applies only in certain cases (depending on the set-
tings of Chapter 4.10, page 100 and Chapter 4.11, page 103), it is recommended to always use "at" or "AT".
Examples
EXAMPLE 1
<BER>
(num)
at^smond
execute command
^SMOND:262,01,3008,6060,32,100,66,,,0,,,0
,
262,01,3008,DDD1,35,92,80,
262,01,3008,,31,96,83,
262,01,3008,BFBE,35,27,86,
262,01,3008,,32,98,88,
262,01,3008,BB44,32,90,89,
262,01,3008,8307,31,22,93,
2,23,99
response as for write command with <format>=15
(Line breaks inserted for readability in print)