EasyManua.ls Logo

Siemens TC35i Terminal

Siemens TC35i Terminal
439 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC35i AT Command Set
2.14 AT^SCFG
s
m
obil
e
TC35i_ATC_V02.07 Page 58 of 439 1/30/04
Confidential / Released
EXAMPLE 3
Switch off the TC35i after three minutes without restart.
For details regarding software controlled power down refer to
AT+CFUN and AT^SMSO.
After three minutes:
AT^SCFG="AutoExec",1,1,3,0,"AT^SMSO","000:03:00"
...
OK
^SCFG:"AutoExec",0,1,3,0,"AT^SMSO"
OK
"AT^SMSO" command entry confirmation
^SHUTDOWN
"AT^SMSO" command response

Table of Contents

Related product manuals