Operation
20222121A 31
Seastate filter
OFF: Seastate filter is disabled.
AUTO: Automatically reduces rudder activity and
autopilot sensitivity in rough weather by
an adaptive process (default).
MANUAL: Manual yaw band adjust (1-10, 10 ±6°).
The manual setting determines the number of degrees the vessel
may deviate from the set course before any command is given to
the rudder. The AUTO setting is recommended. The MANUAL
settings may be used to find the optimum combination of course
keeping and low rudder activity in rough but steady sea
conditions.
NAV WIND setting, see page 27
Source select, see page 27
NAV Mode
The User setup for NAV mode is similar to the User setup for
AUTO mode. It does however not include the Nav/Wind and the
Source select items.