Questions and Answers

  • M
    Matthew ChangSep 10, 2025
    What to do if the SMA Cluster Controller does not send any data to the external FTP server?
    • M
      Mark TaylorSep 12, 2025
      If the Cluster Controller isn't sending data to the external FTP server, ensure that there is enough storage space available on the FTP server. Also, ensure that the login data for the FTP server are correct and that the "Append" function is activated in the FTP server.
  • E
    Emma AlexanderSep 9, 2025
    Why is an incorrect total number of connected inverters shown on the user interface or the display of my SMA Controller?
    • Q
      qdonaldsonSep 9, 2025
      An incorrect total number of connected inverters might be displayed because communication with at least one inverter is disturbed. Either the Cluster Controller has not yet registered with one or more inverters, or the connection to one or more inverters has been interrupted. Wait six minutes and check again whether the correct number of all connected inverters is displayed. Ensure that the inverters are in operation. Ensure that the network cables that connect the inverters with one another are correctly connected. Ensure that the network cable of the inverter connected directly to the Cluster Controller is connected to network port X9 or X10 of the Cluster Controller. Ensure that no network components, network cables or connectors are defective.
  • M
    Michelle WilliamsonSep 7, 2025
    What to do if the SMA Cluster Controller does not send any data to Sunny Portal?
    • T
      Tiffany OliverSep 8, 2025
      If the Cluster Controller isn't sending data to Sunny Portal, it might be due to incorrectly configured data transmission. If the Cluster Controller is not yet registered in Sunny Portal, register it. Also check the settings for Sunny Portal and test the connection to Sunny Portal.
  • I
    Ivan QuinnAug 22, 2025
    Why does the login page not open for my SMA Network Hardware?
    • H
      hcameronAug 23, 2025
      The login page might not open due to several reasons. First, ensure the patch cable is correctly connected to the Cluster Controller. Then, check for any defective or damaged network components, patch cables, or plug connectors and replace them if necessary. Also, verify the network settings of all network components and adjust them if required. As an additional step, you can restart the Cluster Controller by disconnecting it from the voltage supply and reconnecting it. Note that this can lead to loss of plant data.
  • J
    Juan KimSep 5, 2025
    What to do if the login page does not open on SMA Controller and there is a problem in the LAN?
    • M
      Matthew LeeSep 5, 2025
      If the login page doesn't open and there is a problem in the LAN, ensure that the network cables are correctly connected to the Cluster Controller. Check whether the network components, network cables or connectors are defective or damaged and replace them if needed. Also, verify the network settings of the individual network components and adapt them if required. As a last resort, restart the Cluster Controller by disconnecting it from the voltage supply and reconnecting it. Note that this can lead to loss of system data.
  • C
    Colton SmithSep 4, 2025
    Why aren't the expected binary values for the digital signal source showing on my SMA Network Hardware display?
    • C
      Carmen ChambersSep 4, 2025
      If the expected binary values for the digital signal source are not showing on the display, ensure that the digital signal source is correctly connected.
  • B
    briggsmichaelSep 3, 2025
    Why aren't measured values for the temperature sensor showing on my SMA Network Hardware display?
    • S
      Sheri BrownSep 3, 2025
      If no measured values are displayed for the connected temperature sensor, ensure that the temperature sensor is correctly connected.
  • B
    Brian HarrisSep 2, 2025
    What to do if login to the user interface has failed on SMA Network Hardware?
    • M
      mckayadrianSep 2, 2025
      If login to the user interface has failed, wait for 15 minutes, then log in with the correct plant password.
  • A
    Anthony GarciaSep 1, 2025
    What to do if there's no current signal from the analogue signal source or sensor on my SMA Network Hardware display?
    • C
      christopherlambertSep 1, 2025
      If there's no current signal showing for the analogue signal source or the sensor, ensure that the analogue signal source and the sensor are correctly connected.
  • J
    Jennifer HoffmanAug 31, 2025
    How to connect SMA Network Hardware Cluster Controller to the voltage supply?
    • H
      Hannah LaneAug 31, 2025
      Ensure that the three-pole plug for the voltage supply is connected to terminal X1 of the Cluster Controller.

Summary

Safety

2.1 Intended Use

Specifies the product's intended application and limitations.

2.2 Safety Information

Provides essential safety instructions for product operation and handling.

Product Description

3.1 Cluster Controller Features

Details the Cluster Controller's functions, LEDs, display, and keypad.

3.2 Sunny Portal Integration

Introduces Sunny Portal as an internet platform for monitoring and data visualization.

User Interface Navigation

4.1 User Groups and Rights

Explains user groups and their respective access rights and permissions.

4.2 User Interface Structure

Overview of the UI components including toolbar, system tree, and device menus.

Logging In and Out

Logging Into the Cluster Controller

Step-by-step guide on how to access the cluster controller's user interface.

System Settings

Device Configuration

7.2 Parameter Settings

Configuring parameters for device classes or individual devices.

Exporting System Data

System Monitoring

9.2 Setting Alarms

Configuration for receiving email notifications for alarm-related events.

Grid Management Services

13.1 Implementing Service Setpoints

Explains open-loop and closed-loop control for grid service setpoints.

13.2 Inverter Parameter Setup

How to configure inverter parameters for grid management services.

13.3 Active Power Limitation

Detailed configuration for limiting active power output.

13.4 Reactive Power Setpoint

Configuration options for setting reactive power.

13.5 Fallback Settings

Configuring fallback modes for grid management services.

Update

14.1 Automatic Update

Setting up automatic firmware updates for the cluster controller and connected devices.

14.2 Manual Update

Procedures for performing manual firmware updates.

Passwords and SMA Grid Guard

15.5 SMA Grid Guard Mode Setup

How to activate and configure the SMA Grid Guard mode.

Troubleshooting

18.1 LED States

Explains the meaning of different LED statuses and corresponding corrective actions.

18.2 Controller;Device Errors

Lists common problems and their solutions for the controller and connected devices.

18.4 Controller Reset

Steps to reset the cluster controller to default settings or specific configurations.

SMA CLUSTER CONTROLLER Specifications

General IconGeneral
Data LoggingYes
DisplayLCD
Power Supply24 V DC
Remote MonitoringYes
Protection ClassIP20
Communication InterfacesEthernet
Product TypeController
ManufacturerSMA

Related product manuals