ALC404 LIGHTING TOWER CONTROLLER USER MANUAL
ALC404 Lighting Tower Controller 2018-11-06 Version 1.1 Page 35 of 83
7.2 GENERIC PARAMETER SETTINGS
Table 19 – Generic Parameter Settings
It is time from remote start
signal is active to genset
started.
It is time from remote start
signal is deactivated to
genset stopped.
It is pre-energized time of
glow plug before starter is
powered up.
It is starter each power-up
time.
It is waiting time to
repower-up when the
engine starts fail.
During this time, alarms
including low oil pressure,
high temperature, under
speed, gen under
frequency, gen under
voltage, and fail to charge
are deactivated.
It is genset idle running time
while starting up.
After generator entering into
high speed running, it is
warming up time before
ramp-on load.
After genset ramp-off load,
it is cooling time before
genset stop.
It is genset idle running time
while stopping.
It is electromagnet
power-down time when to
sop.
When ―ETS Solenoid Hold‖
time set as 0, it is time
needed from idle delay
expired to genset stop
completely; when ―ETS
Solenoid Hold‖ time not set