Sirius 800 www.snellgroup.com Nucleus Upgrade (RollCall) and Maintenance
Issue 1 Rev 1 Page 102 © 2014 Snell Limited
9.5.7 Enable/Disable RollCall on a Nucleus2 Controller Using the Online Editor
RollCall is enabled by default on the Nucleus2 2463 router control module and can be
disabled using the Workbench Online Editor if RollCall if required.
To connect computer to the Nucleus2 2463 controller using RollCall the RollCall Command
Set Files must be transferred to the controller (see section 10.2.4 for details) and RollCall
must be enabled (see below).
Nucleus2 2463 Router Control Module Navigate to:
ConfigurationItems | RollCall
• Enabled = set to True to enable RollCall and False to disable RollCall. The other
settings are shown with their default values and they need not be changed unless
instructed to do so by Snell Support.
• StartupDelay = 5
• SharePort = 2050
• BridgePort = 2600
• BridgeRemoteAddress = 128.1.1.1
• BridgeAutoConnect = False
• Name = Router
• Information1 = Info1
• Information2 = Info2
• NetNibbles = 1000
• UseLongNames = False
Connect to the controller by typing the controller IP address into the address bar of your web
browser. When the Nucleus2 web page is displayed click on the RollCall Control tab and the
RollCall web applet will start.
Note:
• Changes will not take effect until the controller has been reset.
• If two Nucleus2 controllers are fitted in a router then the second one must also be
enabled for RollCall.