9.5.8 Enable/Disable Auto Change Over of Controller Ethernet Connection
If a Nucleus2 2463 controller looses its Ethernet connection the system will auto change over
to the second Nucleus2 controller (if a second controller is fitted and auto change over is
enabled). The auto change over function using the Generic Online Editor. Auto change over is
disabled by default.
Nucleus2 2463 Router Control Module Navigate to:
ConfigurationItems | MiscellaneousFeatures
AutoChangeoverIfNoNetworkTime = -1 (see below for details)
Auto change over can be enabled by setting the parameter to a number greater than or equal
to Zero, This number is the time, in seconds, that the controller will wait after loosing network
connection before changing over to the second controller.
Note:
The default Auto Change Over Time is -1 = disabled.
Changes will not take effect until the controller has been reset.
If two Nucleus2 controllers are fitted in a router then the second one must also be
configured with the same auto changeover settings.