Technical Specifications
SolarEdge Installation Guide – MAN-01-00002-1.6
108
Appendix B
Technical Specifications
About This Appendix
The table in this appendix provides the technical specifications of the SolarEdge
system components.
Single Phase Inverter
Rated AC Power Output 3000 3800 5000 5200@208V
6000@240V
5200@208V
6000@240V
W
Maximum AC Power Output 3000 3800 5000 5200@208V
6000@240V
6000@277V
5200@208V
6000@240V
7000@277V
W
AC Output Voltage Minimum –
183 – 208 – 229 /
183 – 208 – 229 / 211 – 240 – 264 /
Vac
AC Frequency Minimum – Nominal –
Maximum
59.3 – 60 – 60.5 Hz
Max. Output Fault Current and
Duration 208V Grid
16 / 20 20 / 20 26 / 20 27.5 / 20 27.5 / 20 A /
ms
Max. Output Fault Current and
14 / 20 17.5 / 20 23 / 20 27.5 / 20 27.5 / 20 A /
Max. Output Fault Current and
Duration 277V Grid
--- --- 20 / 20 24 / 20 28 / 20 A /
ms
Max. Continuous Output Current 208V
14.5 18.5 24 25 25 A
Max. Continuous Output Current 240V
Grid
12.5 16 21 25 25 A
Max. Continuous Output Current 277V
--- --- 18.5 22 25 A