Technical Specifications
SolarEdge Installation Guide – MAN-01-00002-1.6
110
Standard Compliance
Safety
IEC-62103 (EN50178), Draft IEC-62109
Grid Connection Standards VDE 0126-1-1, AS-4777, RD-1663, DK 5940, IEEE1547
Emissions FCC part15 class B, IEC61000-6-2, IEC61000-6-3, IEC61000-3-11,
RoHS Yes
Installation Specifications
AC Output ¾” Conduit
Dimensions (H x W x D)
x 7 /
540 x 315
x 172
27.5 x 12.5 x 7.5 / 540 x 315 x 191 in/mm
Dimensions (H x W x D) with AC/DC
Switch
x 7 /
775 x 315
30.5 x 12.5 x 7.5 / 775 x 315 x 191 in/mm
Weight 42 / 19 45 / 20.5 lb/kg
Cooling Natural Convection
Minimum and Maximum Operating
-4 / -20 ; -40 / -40 to +120 / +60** ˚F/˚C
Protection Rating NEMA 3R
* Higher input DC power may be installed; analyze yearly AC performance.
** Power de-rating over 120F/50C. Refer to Appendix D, Inverter Power De-rating on
page 118 for details.