Technical Specifications
SolarEdge Installation Guide – MAN-01-00002-1.6
112
OP250-LV OP300-MV/
Output During Operation (Power Optimizer Connected to Operating
Maximum Output Current 15 Adc
Operating Output Voltage 5 - 60 Vdc
Total Maximum String Voltage
(Controlled by Inverter) - US and
500 Vdc
Total Maximum String Voltage
(Controlled by Inverter) - EU 3-ph
950 Vdc
Output During Standby (Power Optimizer Disconnected from Inverter
or Inverter Off)
Safety Output Voltage per Power
Optimizer
1 Vdc
PV System Design
Minimum Number of Power
Optimizers per String (1 or More
Modules per Power Optimizer)
8 (1-ph system) / 16 (3-ph
system)
Maximum Number of Power
Optimizers per String (1 or More
Modules per Power Optimizer)
Module power dependent;
typically
20 - 25 (1-ph system)
Parallel Strings of Different
Yes
EMC FCC Part15 Class B,
IEC61000-6-2, IEC61000-6-3
Safety IEC-62103 (class II safety),
UL-94 (5-VA), UV Resistant