The standard ‘trap’ objects that are available for the C100 HDS system in V1.1/5 software are shown in the following table.
+3.,< :86 .;,:29<287
SSLC110Restarting
System System restarting
SSLC110MemLow
System Blackrock DSP card memory low
SSLC110DspReboot
System A DSP device on the Blackrock DSP card has rebooted
SSLC110DspRebootFail
System
A DSP device on the Blackrock DSP card has failed to
reboot
SSLC110Psu1Fail
Processor Blackrock processor PSU 1 failure
SSLC110Psu2Fail
Processor Blackrock processor PSU 2 failure
sslC110PsuFanFail
Processor Blackrock processor fan failure
SSLC110MainGfx1Fail
Console Primary console TFT meter driver failure
SSLC110MainGfx2Fail
Console Secondary console TFT meter driver failure
SSLC110LostTileComms
System Lost Ethernet communication to the control surface
SSLC110ResumedTileComms
System
Recovered Ethernet communication with the control
surface
SSLC110Synclost
System External (Video/AES) sync lost
SSLC110SyncReturned
System External (Video/AES) sync recovered
SSLC110NowActiveInRedundantPair
System
Blackrock processor is now the active member of a
redundant pair
SSLC110NowDormantInRedundantPair
System
Blackrock processor is now the dormant member of a
redundant pair
SSLC110DiskStatusNotify
SBC
SBC system disk SMART status trap. This will be sent upon
receiving a SMART error from the system hard disks
SSLC110RaidStatusNotify
SBC
SBC RAID disk array status trap. This will be sent upon
receiving a change in status from the system RAID disk
array manager
C100 HDS Installation Manual Section 4 – Appendices | Page 4-21
SNMP