The individual SNMP objects for B-RIO units that are exported from V1.1/5 software are as follows:
"# $" #
The standard ‘trap’ objects that are available for B-RIO units in V1.1/5 software are as followings:
%"$" "$  #
A great deal of information regarding SNMP is of course available from the internet whilst a highly recommended book is
Essential SNMP, 2nd edition’, published by O’Reilly Media (ISBN10: 0-596-00840-6, ISBN13: 9780596008406).
+3.,< :86 .;,:29<287
sslRioOnline
B-RIO A B-RIO unit has come online
sslRioOffline
B-RIO A B-RIO unit has gone offline
sslRioChassisFan1Fail
B-RIO B-RIO chassis fan 1 failure
sslRioChassisFan2Fail
B-RIO B-RIO chassis fan 2 failure
sslRioPsu1Fail
B-RIO B-RIO PSU 1 failure
sslRioPsu2Fail
B-RIO B-RIO PSU 2 failure
sslRioPsu1FanFail
B-RIO B-RIO PSU 1 fan failure
sslRioPsu2FanFail
B-RIO B-RIO PSU 2 fan failure
+3.,< $?9. .;,:29<287
sslRioIndex
read-only
The index of the B-RIO unit up to 8 units may be
connected and addressed
sslRioPresent
read-only Indicates if a B-RIO unit is connected to the system
sslRioVersion
read-only Carries the B-RIO firmware version string
sslRioTemp1
read-only
Temperature reading in degrees Celcius from the primary
internal temperature sensor
sslRioTemp2
read-only
Temperature reading in degrees Celcius from secondary
internal temperature sensor
sslRio1v2
read-only Voltage reading from the +1.2V rail
sslRio3v3r1
read-only Voltage reading from the +3V3 rail (primary sensor)
sslRio3v3r2
read-only Voltage reading from the +3V3 rail (secondary sensor)
sslRio5v
read-only Voltage reading from the +5V rail
sslRio5v5
read-only Voltage reading from the +5V5 rail
sslRio15V
read-only Voltage reading from the +15V rail
sslRioMinus15V
read-only Voltage reading from the –15V rail
sslRioCardsInfo
read-only
A string providing details of which I/O cards are currently
fitted to this B-RIO
SSLC110NowDormantInRedundantPair
System
Blackrock processor is now the dormant member of a
redundant pair
SSLC110DiskStatusNotify
SBC
SBC system disk SMART status trap. This will be sent upon
receiving a SMART error from the system hard disks
SSLC110RaidStatusNotify
SBC
SBC RAID disk array status trap. This will be sent upon
receiving a change in status from the system RAID disk
array manager
Page 4-22 | Section 4 – Appendices C100 HDS Installation Manual
SNMP

Table of Contents

Other manuals for Solid State Logic C100 HDS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solid State Logic C100 HDS and is the answer not in the manual?

Solid State Logic C100 HDS Specifications

Power IconPower
console power100-240 V AC
power consumption300-700 W
DSP and Audio Processing IconDSP and Audio Processing
maximum input channels256
second input path channels512
utility busses24 mono
aux busses24 mono
dedicated ASG buses16
dedicated PGM buses12
delay modules64 modules, 5.4 seconds each
Weight and Dimensions IconWeight and Dimensions
max height100.6 cm
weight (40 fader)190 kg
height adjustment0 to +1 cm
width (40 fader, flat end trim)143.1 cm
max depth92.6 cm