6-28
DCR-PC350/PC350E
9. Picture Frame Setting
(Color Reproduction Adjustment Frame)
When performing “Color Reproduction Adjustment” and “Mixed
Color Compensation Adjustment”, set the picture frame to “Color
reproduction adjustment frame”.
Subject Color bar chart
(Color reproduction adjustment frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point Video terminal of AUDIO/VIDEO jack
Measuring Instrument Oscilloscope,
TV monitor (Under scan mode)
Specified Value A=B, C=D, E=F
Note1: This adjustment should be carried out upon completion of “HALL
Adjustment” and “Flange Back Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Displayed data of the adjustment remote commander.
1 : XX : XX
XL or YL data
XH or YH data
Switch setting:
1) POWER....................................................... CAMERA-TAPE
2) NIGHT SHOT..................................................................OFF
3) FOCUS.................................................................. MANUAL
4) DIGITAL ZOOM (CAMERA SET menu) ......................OFF
5) STEADY SHOT (CAMERA SET menu) ........................OFF
Setting method:
1) Adjust the zoom and the camera direction, and set to the
specified position.
2) Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Order Page
Address
Data Procedure
1 0 03 18 Set the data.
2 1 Read XH data and XL data.
(Note3)
3 0 03 22 Set the data.
4 1 Read YH data and YL data.
(Note3)
Note4: When using the clear chart, remove the color bar chart from the
pattern box and insert a clear chart in its place. (Do not perform
zoom operations during this time.)
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page
Address
Data Procedure
1 6 90 XL Set the data. (Note5)
2 6 91 XH Set the data. (Note5)
3 6 92 YL Set the data. (Note5)
4 6 93 YH Set the data. (Note5)
5 6 01 79 Set the data, and press PAUSE
button.
Note5: XL, XH, YL and YH are the data read in the “Setting method”.
Note6: This picture frame setting can be released in the following method.
How to release the picture frame setting:
Order Page
Address
Data Procedure
1 0 10 00 Set the data.
2 6 01 00 Set the data, and press PAUSE
button.
3 6 90 00 Set the data.
4 6 91 00 Set the data.
5 6 92 00 Set the data.
6 6 93 00 Set the data.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
A=B
C=D
A
BC
D
Color bar chart picture frame
Monitor TV picture frame