6-51
DCR-PC350/PC350E
3. Serial No. Input
3-1. Company ID Input
Write the company ID in the EEPROM (nonvolatile memory).
Page C
Address E0, E1, E2, E3, E4
Note: The data of page: 0, address: 10 must be “00”.
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: C, addresses: E0 to E4.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
7) Obtain the difference D4 between D2 and D3.
(Decimal calculation, 0
D4 255)
D4 = D2 – D3
Example:If D2 is “12345” and D3 is “12288”.
D
4 =12345 – 12288 = 57
8) Convert D4 to hexadecimal, and take this as H4.
(Refer to “Hexadecimal-decimal conversion table” in “6-4.
Service Mode”.)
Example:If D4 is “57”.
H4=39
9) Input the upper 2 digits of H3 to page: C, address: E6.
Example:If H3 is “3000”.
Select page: C, address: E6, set data: 30, and
press the PAUSE button.
10) Input H4 to page: C, address: E7.
Example:If H4 is “39”.
Select page: C, address: E7, set data: 39, and
press the PAUSE button.
11) Select page: 0, address: 01, and set data: 00.
Address
E0
E1
E2
E3
E4
Data
08
00
46
01
02
3) Select page: 0, address: 01, and set data: 00.
3-2. Serial No. Input
Write the serial No. and model code in the EEPROM (nonvolatile
memory). Convert the serial No. on the name plate from decimal to
hexadecimal, and write in the EEPROM.
Page C
Address E5, E6, E7
Note: The data of page: 0, address: 10 must be “00”.
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the serial No. on the name plate, and take it as D1.
Example:If the serial No. is 77881.
D1=77881
Note: Use six digits of the low rank when a serial No. is more than
seven digits.
3) Obtain D2 and H1 corresponding to D1 from Table 6-3-2.
Example:If D1 is “77881”.
D2 = D1 – 65536 = 12345
H1 = FE
4) Input H1 to page: C, address: E5. (Model code input)
Example: If H1 is “FE”.
Select page: C, address: E5, set data: FE,
andpress the PAUSE button.
5) Obtain the maximum decimal not exceeding D2 from Table 6-
3-3, and take this as D3.
Example:If D2 is “12345”.
D3 = 12288
6) Obtain the hexadecimal corresponding to D3 from Table 6-3-
3, and take this as H3.
Example:If D3 is “12288”.
H3 = 3000
D1 (Decimal)
000001 to 065535
065536 to 131071
131072 to 196607
196608 to 262143
262144 to 327679
327680 to 393215
393216 to 458751
458752 to 524287
524288 to 589823
589824 to 655359
655360 to 720895
720896 to 786431
786432 to 851967
851968 to 917503
917504 to 983039
983040 to 999999
D2 (Decimal)
D1
D1 – 65536
D1 – 131072
D1 – 196608
D1 – 262144
D1 – 327680
D1 – 393216
D1 – 458752
D1 – 524288
D1 – 589824
D1 – 655360
D1 – 720896
D1 – 786432
D1 – 851968
D1 – 917504
D1 – 983040
H1 (Hexadecimal)
(Service model code)
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
Table 6-3-2.