6-11
DCR-PC350/PC350E
1-2-2. INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
1. Initializing the 8, C, 18, 1C Page Data
Note1: If Initializing the 8, C, 18, 1C Page Data is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2: If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Adjusting page 8
Adjusting Address 00 to FF
Adjusting page C
Adjusting Address 10 to FF
Adjusting page 18
Adjusting Address 00 to FF
Adjusting page 1C
Adjusting Address 00 to FF
Initializing Method:
Order Page
Address
Data Procedure
1 0 01 01 Set the data.
2 0 10 00 Set the data.
3 3 81 Check that the data is 00.
4 3 80 0C Set the data, and press PAUSE
button.
5 3 80 Check that the data changes to
1C.
6 Perform Modification of 8, C,
18, 1C Page Data.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the Fixed data-2 address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3) When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to 00.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page data
Order Page
Address
Data Procedure
1 0 10 00 Set the data.
2 2 00 29 Set the data.
3 2 01 29 Set the data, and press PAUSE
button.

Table of Contents