ICP-X7000
2-3 (E)
5. When a blank panel is removed and an operation module is installed, lay a fine-wire coaxial cable
between the installation location and the PIF-53 board, connect the cable to the connector (CN1103),
and then clamp it with clampers.
t
. Clamper positions vary depending on the operation module installation location.
. There is no indication “RED” near the connector on the PIF-53 board. Connect the fine-wire coaxial
cable with the red lead upward.
. Connectors to which a fine-wire coaxial cable is to be connected vary depending on the operation
module installation location.
PIF-53 board
CN1100: MKS-X7017/MKS-X7018/MKS-X7019
CN1101: Any operation module
CN1102: Any operation module
CN1103: Any operation module
. When a blank panel is installed, connect the modules on the right side of the blank panel without
providing a space.
Cable Clamp Fine-wire coaxial cable
Clamper Clampers
PIF-53 board
Fine-wire coaxial cable
Lead (red)
CN1103
PIF-53 board
CN1100
CN1102
CN1101