Maintenance Waukesha Cherry-Burrell
®
Brand Universal 3 Pump
Page 36 95-03103 11/2018
Single and Double
Mechanical Seal
Remove Product-Side Rotary and Stationary Seal
1. Remove the rotary seal from the rotor.
2. Remove the rotary seal O-ring from the rotor.
3. Remove the stationary seal from the pump body.
Figure 41 - Remove rotary seal
Figure 42 - Remove seal O-ring
Figure 43 - Remove stationary seal