11. Technical features
ANGLE MEASUREMENT
Accuracy
1
2”
Reading system
Absolute encoder
Display resolution
(selectable)
1/5/10
0.0001g/0.0005g/0.001g
0.01mil/0.05mil/0.1mil
Angle Units
DEG 360°/GON 400/MIL 6.400
TELESCOPE
Magnification/ Field of view
30x/1°30’
Tube length
156 mm
Minimum focus distance
1.0 m (3.26 ft)
Reticle
ON/OFF
Objective aperture
ɸ 45 mm
Laser pointer
Red light, coaxial
TILT SENSOR
Type
Electronic, dual-axis
Compensation range/accuracy
± 3.0'/1”
DISTANCE MEASUREMENT RANGE
2
Standard mode prism
3.000 m
3
Long mode prism
5.000 m
4
Reflective sheet (6cm x 6cm)
800 m
4
Reflectorless
600 m
4
1.000 m
4-5
DISTANCE MEASUREMENT ACCURACY
6
Standard mode prism
2 mm + 2 ppm
Long mode prism
2 mm + 2.5 ppm
Reflective sheet (6cm x 6cm)
3 mm + 2 ppm
Reflectorless
3 mm + 2 ppm
MEASUREMENT TIME
Standard mode/Prism
(Tracking/Fast/Fine)
0.4/0.6/1.0 sec
Reflectorless
1.5÷5 sec
DISTANCE MEASUREMENT
Distance Unit
m/US ft/INT ft
Display Resolution
0.001m
0.01ft
LASER PLUMMET
Laser type
635nm semiconductor laser
Accuracy
1mm/1.5 m
Spot
± 1.5mm/1.5 m
LEVEL VIAL SENSITIVITY
Plate level
30“/2mm
Circular level
8‘/2mm
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20° C +50° C
Storage Temperature
-40° C +70° C
Waterproof/Dustproof
IP55
PHYSICAL SPECIFICATION
Dimensions
206 x 203 x 360 mm
Weight including battery
and tribrach
6.0 Kg
POWER
Battery Voltage/Capacity
7.4V/3.400mAh Li-ion
Operating time
(angle measurement)
13 hours
Operating time
(distance meas. every 30 sec)
12 hours
Operating time
(angle + distance meas.)
6 hours
Battery charger
110/220V, charging time 4h
OTHER SPECIFICATIONS
Display/Keyboard
Two sides, LCD 240x128
Dots/Alphanumeric
Memory
4Gb internal
SD card (max 16Gb)
Interface
RS-232C/mini USB/SD card/
Bluetooth
Sensor
Temperature/Pressure
ON BOARD FIELD APPLICATION PROGRAMS
Data recording and management, Stake out, Area & volume, Target
offset, Hidden point, COGO, Tie distance, Remote height, Height
transfer, Free station, Line/Arc stake out, Construction, Lead measure,
Road
Specifications subject to change without notice.
1
Standard deviation based on ISO 17123-3
2
Good condition: no haze, visibility about 40km, no heat shimmer, breeze. Under optimal conditions on Kodak Grey Card (90% reflective)
3
Class 1
4
Class 3R
5
R25LR Model
6
Standard deviation based on ISO 17123-4