Stonex R25/R25LR Total Station - User Manual 45
NOTE:
Make sure that the target setting in the instrument matches the type of target used.
If the objective lens is dirty, it will affect the accurate of measured results. Dust it off with your special
brush and wipe it with your special cloth (in your carrying case) before putting away.
If an object with a high reflective factor (metal, white surface) exists between the instrument and the
target when measuring, the accuracy of the measured results will be affected.
An angle is also able to be measured while distance measurement is in course.
Measurement will automatically stop after a single measurement if the EDM mode is single.