HTTP, HTTPS, or FTP (FTPS when available).
Server Address: Enter the address of the server in this field. This may be an IP address, or a
domain name if a DNS server has been configured on the System Settings page. Literal IPv6
addresses must be surrounded with square brackets. Example: the address fdda:2301: :2
must be entered as [fdda:2301: :2].
User Name: Enter the user name in this field if required by the server. Note that this is not
available for TFTP.
Password: Enter the password in this field if required by the server. Note that this is not
available for TFTP.
Anonymous Download: Check this box if no User Name and Password are required by the
remote server.
Remote Filename: Enter the remote .fwb firmware file name into this field. The full path is
required.
MD5 Checksum (Optional): If an MD5 checksum of the file is available, it may be entered
into this field. Providing a checksum will ensure the firmware arrives at the switch intact and
without any glitches. An MD5 checksum is not required.
4-13
Chapter 4 - Managed Switch Software Setup
Stride Industrial Ethernet Switches User Manual 2nd Ed. Rev. A