228 SPARCstation 20 Service Manual • July 1996
Example:
power-off
The power-off command turns off the system power. A Type-5 keyboard must be
attached for this command to work.
module-info
The module-info command is used to display the installed MBus module type and
MBus module and SBus card clock speeds. If multiple MBus modules are installed,
the module-info command identifies each module individually.
CODE EXAMPLE E-9
identifies the module-info command output message for a uniprocessor.
CODE EXAMPLE E-10 identifies the module-info command output message for
multiprocessor.
ok setenv selftest-#megs XX
CODE EXAMPLE E-9 Uniprocessor module-info Command Output Message
ok module-info
MBus: 40.00 MHz
SBus: 20.00 MHz
CPU#0: 50.00 MHz SuperSPARC/SuperCache
CODE EXAMPLE E-10 Multiprocessor module-info Command Output Message
<#0> ok module-info
MBus: 50.00 MHz
SBus: 25.00 MHz
CPU#0: 50.00 MHz SuperSPARC
CPU#2: 50.00 MHz SuperSPARC