2-116 SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
7. Use the showdomainstatus(8) command to confirm the domain ID 2 status.
(See
TABLE 2-22.)
Note – When adding the system board to the domain using DR functions that
operate the XSB without stopping the domain, see the Dynamic Reconfiguration User’s
Guide.
XSCF> showboards –va
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-0 02(00) Assigned y y y Passed Normal n
01-0 02(07) Assigned y y y Passed Normal n
01-1 02(08) Assigned y y y Passed Normal n
01-2 02(09) Assigned y y y Passed Normal n
01-3 02(10) Assigned y y y Passed Normal n
XSCF> showdomainstatus –a
DID Domain Status
00 -
01 -
02 Running
03 -