figure 8-33 Battery Discharge Time
8.12.9 Battery Forced Charge Time
Tap Settings→Energy Management Parameter→Battery Forced Charge Time to enter
the corresponding screen.
These are the times of day at which the inverter will start charging the battery with rated AC
power.
figure 8-34 Battery Forced Charge Time
When there is no PV power, the power imported from the grid charges the energy system
during the time period until the target SOC is reached.
It is recommended to set the time period in off-peak tariff time. The time period 1 is in priority
to the time period 2 if two periods overlap. The charging energy comes from the excess PV
energy in priority and then from the grid. The inverter will take charging power from the grid
in the case of PV energy shortage.
8 iSolarCloud App User Manual