The intelligent mode is disabled in an off-grid system.
• When the inverter is installed to retrofit an exisiting PV system, the upper limit of opti-
mized power is the sum of the rated power of the hybrid inverter and the rated power of
the existing PV inverter.
• Once the intelligent mode is enabled, the DO relay will remain connected for 20 minutes
after the DO connection.
Take 09:00 am–09:30 am and the optimized power of 1000 W as an example.
figure 8-38 DO Operation in Intelligent Mode
8.12.11 Communication Parameters
Tap Settings→Communication Parameters to enter the screen, as shown in the following
figure.
figure 8-39 Communication Parameters
• The device address ranges from 1 to 246.
• The IP adress, gateway, subnet mask, preferred DNS server and alternate DNS server
can be modified only when the DHCP is set to Off.
• Acquire the IP adress, gateway, subnet mask, preferred DNS server and alternate DNS
server from the network professional.