153
**** Peak power only for Resistive loads. Detail refer to SHRT backup output power
document.
11.2 The Compatibility for Backup under Off-grid Scenario
The information below is about the compatibility for backup of SUNGROW SH5.0–10RT /
SH5.0–10RT-20 inverter under off-grid scenario. Please refer to this information before you
use the back-up model of the four inverters under off-grid situation.
Main electrical panel
Type
Load Power
SH5.0RT/
SH5.0RT-20
SH6.0RT/
SH6.0RT-20
SH8.0RT/
SH8.0RT-20
SH10RT/
SH10RT-20
Dust collector 1 kW 1 kW 1 kW 1.3 kW
Water heater / Kettle
/ Iron / Oven / Toast-
er / Geothermal
blanket / Rice
cooker
1.5 kW 1.8 kW 2.4 kW
3 kW (2.5 kW
with SBR096)
Microwave oven 1 kW 1 kW 1.3 kW 1.5 kW
Refrigerator
1 kW 1 kW 1 kW 1 kW
TV / Computer
1 kW 1 kW 1 kW 1 kW
Bath heater 1 kW 1.5 kW 2 kW 2.5 kW
Fluorescent / LED
lights
1 kW 1 kW 1 kW 1.3 kW
Electric fan / Ceiling
fan
1 kW 1.2 kW 1.6 kW 2 kW
Additional large appliances
Type
SH5.0RT/
SH5.0RT-20
SH6.0RT/
SH6.0RT-20
SH8.0RT/
SH8.0RT-20
SH10RT/
SH10RT-20
Conditioner (Fre-
quency conversion)
1P 1P 1P 1.5P
The data of the compatibility for backup of SH5.0–10RT / SH5.0–10RT-20 are
based on the test with SUNGROW SBR096/128/160/192/224/256 batteries (-20 ~
53 ℃, 5~100% SOC). For the actual application, please refer to the maximum out-
put capacity of the battery used.
For those loads that not covered in this document, please contact SUNGROW to make sure
the compatibility of the specific loads under off-grid scenario. SUNGROW will not be held re-
sponsible for the usage of any load without confirmation. We will keep updating this docu-
ment, please contact SUNGROW if there are any relevant issues.
User Manual 11 Appendix