EasyManua.ls Logo

Sungrow SH10RT - Communication and Configuration; EV Charger Management

Sungrow SH10RT
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
the maximum discharge current of the inverter (30A);
the maximum / recommended discharge current from the battery manufacturer.
For this reason, the battery discharge power may not reach the nominal power.
If the PV voltage is higher than 900 V, the battery cannot discharge.
The hybrid system will start to discharge the battery when the import power
value exceeds a threshold value of 70 W.
3.4 Communication and Configuration
The inverter possesses various ports for device and system monitoring, including RS485,
Ethernet, WLAN, and CAN; various parameters can be configured for optimal operation.
The inverter information is accessible through the iSolarCloud App.
3.5 EV Charger Management
The currently supported EV Charger brands and models are shown in the following table.
Brand Model Firmware Version
SUN-
GROW
AC011E-01 ≥V1.2.469
3 Function Description User Manual

Table of Contents

Other manuals for Sungrow SH10RT