OPERATION & MAINTENANCE MANUAL SWE155F
155
4.5.6.4 Cleaning Air Filter Element
Stop the machine at level ground, lower bucket to
ground.
Shut auto-idle speed switch to run engine unloaded at
low speed for 5 minutes.
Important
Stopping the engine improperly may damage
turbocharger.
Set start key to OFF position, stop the engine, remove
the key from starting lock, set pilot safety lever to
LOCK position.
Loosen clamp buckle (2) to remove air filter front
cover.
Remove outside filter (1), clap slightly by hand, never
hit with hard object.
Note
Minimize pressure of compressed air (<0.2
MPa,
2kgf/cm2, scatter personnel around to avoid
scattered broken pieces, wear personal
protective articles including goggles and
protective glassed.
Use compressed air to clean outside filter (1),
following the wrinkle direction to blow air outward.
Clean up the inside filter.
Install outside filter (1), end cover, fasten clamp
buckle (2).
Start engine; run it unloaded at low speed. Check filter
clogging indicator on monitor. If this indicator
illuminates, shut engine immediately and replace
outside filter (1).
Replace internal filter element (3) the moment outside
filter element (1) is replaced.
4.5.6.5 Checking Hoses and Pipeline Leakage, Interference wear-out.
For details, please refer to chapter 4.5.1.6.