EasyManua.ls Logo

Suzuki DL650K5 - C49 Pair Control Solenoid Valve Circuit Malfunction

Suzuki DL650K5
701 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FI SYSTEM DIAGNOSIS 4-45
“C49” PAIR CONTROL SOLENOID VALVE CIRCUIT MALFUNCTION
INSPECTION
Step 1
1) Remove the fuel tank. ("5-7)
2) Turn the ignition switch OFF.
3) Check the PAIR control solenoid valve coupler for loose or
poor contacts.
If OK, then measure the PAIR control solenoid valve resis-
tance.
4) Remove the air cleaner box. ("5-15)
5) Disconnect the PAIR control solenoid valve coupler and mea-
sure the resistance between terminals.
% PAIR control solenoid valve resistance:
20 – 24 at 20 °C/68 °F
! 09900-25008: Multi circuit tester set
& Tester knob indication: Resistance ()
Is the resistance OK?
DETECTED CONDITION POSSIBLE CAUSE
PAIR control solenoid valve voltage is not input in
ECM.
PAIR control solenoid valve circuit open or short.
PAIR control solenoid valve malfunction.
ECM malfunction.
1
YES Go to Step 2
NO
Loose or poor contacts on the ECM coupler.
Replace the PAIR control solenoid valve with a
new one.
1